By performing a HTTP request to set the desired WiFi settings (see HTTP API below). hold for 5 seconds to reset WiFi settings. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. They publish a JSON payload similar to the one in /status. The device can be configured to measure three separate points of a mono-phase electrical system and measure each of them separately. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. – Man sollte danach in der Geräteinfo nachsehen, ob bereits eine 12-stellige ID vorhanden ist. Shelly devices announce a HTTP service on port 80 via mDNS. Works only when button is configured as, URL to access when SW2 input is pressed briefly. Roller Shutter. change the purple MQTT path to reflect your MQTT prefix you set above, Each current sensor in the EM (there are 2) outputs 7 messages. Set illumination level threshold for dark condition. The Device has an embedded Web Interface which can be used to monitor and control the device, as well as adjust its settings. Shelly Vintage supports the following actions, which can be set as described at /settings/actions: Shelly Duo - Wi-Fi on board, Cloud and MQTT enabled, dimmable, 2700K up to 6500K, voice control, smart Wake-up and Night mode. The professional 3-phase energy meter. Now we can start setting up the device over MQTT. Shelly Duo only supports a single channel, indexed as, Output channel settings. Wir hoffen, das ist OK! Shelly2.5 supports the following actions, which can be set as described at /settings/actions: Shelly2.5 adds information about the current state of the output channels, the logical "roller" device and power metering. Hi First time purhcase of Shelly EM products - I've ordered x2 Pro 3EMs to install in home consumer box (EU voltage, single phase). For example, a Shelly1 will always include a description of properties related to external (add-on) sensors, even if they are not currently attached (but of course, in this case they will be hidden from the status packet). Count: Red light will be flashing when the Device is measuring energy according to settings with frequency dependent on the energy flowing through the measured circuit. Enable the open window mode of operation. However, you need to check two things here: whether the connection is enabled and whether your server is set correctly. Die eingebettet Web Die Schnittstelle kann verwendet werden, um das Gerät zu überwachen und zu steuern sowie seine Einstellungen anzupassen. Hopefully you find the Youtube video is general / conceptual enough to help here. It is a uint16_t in network byte order which indicates a change in the status report. For this to work, the device must first be successfully calibrated, so that the time it takes for closing and opening are known. Error responses carry a 4xx HTTP response code and a text/plain response body, usually with an informative message for the type of error which occurred. Temperature thresholds: The values of over-/under-temperature thresholds must be inside the ranges measurable by the DS1820/DHT22 sensors: Only applicable if add-on attached (DHT22), Humidity thresholds: The values of over-/under-humidity thresholds must be inside the range measurable by the DHT22 sensor: [0/100]%, Only applicable if low-power switch add-on attached. Information about each output channel is published on: 3 additional parameters are supported on the /settings endpoint for RGBW2 White: Shelly RGBW2 White supports the following actions, which can be set as described at /settings/actions: Each output channel's settings are individually controlled when the device operates in white mode with the exception of btn_type and btn_reverse: they are shared for all channels (and are only visible in /settings/white/0). Shelly Dimmer SL has the same features as Shelly Dimmer, the only difference being that neutral connection is not required. HTTP authentication configuration: enabled flag, credentials. Erfahren Sie, wie Sie Stromkreise mit Shelly-Geräten über Wi-Fi und Cloud-Hausautomatisierungsdienste fernsteuern. To configure the detection of input events, set the parameters described below via the /settings endpoint. The final string should look like: The schedule is set as whole set. Take a quick look at the. Lassen Sie Kinder nicht mit den an das Gerät angeschlossenen Knöpfen/Schaltern spielen. There you should be able to see some new notifications regarding the reconnection of your device. p.s. This endpoint allows sending commands to the dimmer to control it. Shelly2.5 can operate in two distinct device modes: Relay and Wir hoffen, dass diese kleine Anleitung bei dem Anlernen und Einrichten weitergeholfen hat und bei Fragen helfen wir wie gewohnt in unserem Smarthome Forum weiter. List of reasons which woke up the device: Output channel settings. This will allow for easy reconfiguration of peer to peer network. This is a big topic I won’t cover here. Features No HUB required. Shelly1 comes with a programming/debug header which can be used to flash alternative firmwares on the device. Continue with Recommended Cookies, Home » Shelly » Shelly Pro 3EM Dreiphasen-Energiemessgerät Benutzerhandbuch, BENUTZER- UND SICHERHEITSLEITFADENSHELLY PRO 3EMDREIPHASEN-ENERGIEZÄHLER. Shelly®-Geräte können von jedem Ort, an dem der Benutzer über eine Internetverbindung verfügt, aus der Ferne aufgerufen, gesteuert und überwacht werden, solange die Geräte mit einem Wi-Fi-Router und dem Internet verbunden sind. Defalut value: true. Additionally: Shelly1/1PM supports the following actions, which can be set as described at /settings/actions: The returned document here is identical to the data returned in /settings for the single output channel in the relays array. Verwenden Sie das Gerät nur mit einem Stromnetz und Geräten, die allen geltenden Vorschriften entsprechen. Shelly2.5 will measure the time it takes to open and close the mechanical device under control. Max URLs length is 256. http://192.168.33.1/settings/actions?index=0&name=out_on_url&enabled=true&urls[]=http://192.168.1.4/on&urls[]=http://192.168.1.5/on, http://192.168.33.1/settings/actions?index=0&name=out_on_url&enabled=false, http://192.168.33.1/settings/actions?index=0&name=out_on_url&urls[]=, http://192.168.33.1/settings/actions?index=0&name=over_power_url&enabled=true&urls[]=192.168.1.4/overpower&urls[]=192.168.1.5/overpower&over_power_url_threshold=100. Shelly Pro 3EM is a Wi-Fi-operated DIN-mountable 3-Phase Energy Meter with Wi-Fi, Bluetooth, and LAN connectivity. In Roller mode, the integrated power meter of Shelly2 can be used to detect motor overload which usually means something obstructing the movement of the door or roller shutter. I bought both, to compare / contrast and for flexibility. In this mode, an overpower threshold can be enabled for each of the two channels, via the max_power parameter in /settings. das Tablet oder Smartphone befinden, womit wir gerade die Webseite aufgerufen haben. This segment will be always concatenated. Check messages are coming in to InfluxDB. complete current state. Shelly2 will measure the time it takes to open and close the mechanical device under control. turn the device on, either by re-inserting the battery or pressing the button shortly; then press and hold the built-in user button for more than 10 seconds. Here is some information what I already digged out. Shelly EM supports up to 20 schedule rules. The offset from the UTC timezone in milliseconds. there isn’t one.). Configuration. Instead, it will just report the event and go back to sleep. Wenn man über die Android Shelly App gegangen ist, wird die App nun automatisch das Gerät im WiFi hinzufügen. However, we do not recommend using retained MQTT messages. Shelly Pro 3EM supports mTLS for MQTT, HTTP, and secure outbound WebSockets. Sets the operating mode for the sensor depending on light conditions. The factory default is AP mode with SSID shelly-XXXXXXXXXXXX with no authentication enabled. Transition time between on/off and color change, [0-5000] ms, Whether the logical state of the input is inverted, Set transition time between on/off and color change, [0-5000] ms, Sets a default timer to turn ON after every OFF command in seconds, Sets a default timer to turn OFF after every ON command in seconds, Power and energy information, see description below, Whether an overpower condition has occured, Transition time between on/off and white change, [0-5000] ms, Set transition time between on/off and white change, [0-5000] ms, Set URL to access when input switch is activated, Set URL to access when input switch is deactivated, Set URL to access when input switch is held down, Set URL to access when input switch is pressed briefly, Set URL to access when output is activated, Set URL to access when output is deactivated. Shelly Pro 3EM can be accessed, set up and monitored remotely by the User, as well as the Device can access and communicate with automation system, as long as they are in the same network infrastructure. Zu den Shelly Einstellungen möchten wir an dieser Stelle generell noch ein paar Erläuterungen geben: Das Menü zum Konfigurieren der Geräte ist immer recht ähnlich aufgebaut. blk array should hold list of all "blocks" of the device. Temperature delta (in °C), which triggers an update. When go=to_pos, roller_pos must also be specified and valid. Once the time is synchronized devices can execute commands triggered by user-defined weekly schedule or based on sunrise and sunset times. Provides information about the current WiFi Client mode configuration and allows changes. https://shelly-api-docs.shelly.cloud/#shelly-family-overview, https://shelly.cloud/knowledge-base/devices/shelly-pro-3em/, Shelly PRO 3EM Dreiphasen-Energiemessgerät, Shelly 2246349 Dreiphasen-WLAN-Energiezähler – Benutzerhandbuch, Eltako FWZ12-65A Funk-Einphasen-Energiezähler-Sender Bedienungsanleitung, velleman EMDIN03 Dreiphasen-Energiezähler Benutzerhandbuch, GHiNT MD-01276 Elektronischer Einphasen-Energiezähler für DIN-Schienen, Benutzerhandbuch, C: Phase C und Stromversorgungseingang des Geräts. Will engage after turning the plug ON, Submitting a non-empty value will reset settings for the plug output to factory defaults, Set max time between sequential pushes (ms), URL to access when switch is ON (works only when, URL to access when switch is OFF (works only when, URL to access when switch is pressed short (works only when, URL to access when switch is pressed long (works only when, URL to access when switch is 2x pressed short (works only when, URL to access when switch is 3x pressed short (works only when, URL to access when switch is pressed short + long (works only when, URL to access when switch is pressed long + short (works only when, Submitting a non-empty value will reset settings for this input channel to factory defaults, Set whether to invert the input logical state, Contains the current state of the input channels. It can work standalone in a local LAN and/or Wi-Fi network, or it can also be operated through cloud home automation services through MQTT, HTTP, and WebSocket. The counters array contains the values of the energy counter per channel for the last 3 round minutes. If the open window report is enabled, the device will switch to the correspondig state, Start boost operation for the desired minutes. die zugewiesene IP, die man im Router (z.B. It supports up to three temperature sensors and one humidity sensor. Set max time between sequential pushes (ms), URL to access when switch is pressed short, URL to access when switch is 2x pressed short, URL to access when switch is 3x pressed short, URL to access when switch is pressed long. hold for 10 seconds to perform a complete factory reset. Manage Settings Shelly Dimmer 1/2 is a new smart switch, and this one doesn’t just turn lights on and off, it dims them. ** In case the total load for the three channels drops below 30 VA per phase the measured power level will be displayed, but no consumed energy will be accumulated to the energy statistics and a No load threshold notification will be displayed in the Device web interface and the mobile application. Shelly Bulb RGBW can also play a set of pre-defined effects, specified by a numerical index: Shelly Bulb RGBW allows the simple on and off commands, as well as setting the color, brightness and effects using a JSON payload. Once configured to connect to a WiFi network, it remains in active mode always connected to the WiFi. Open new tab in your terminal and subscribe to the topic /online: You will be able to receive the messages: Now, plug off your device. List of reasons which woke up the device, may contain either of: Whether Rain Mode is enabled (no buzzer and report only when water changes), Enable/disable Rain Mode (no buzzer and report only when water changes), Illumination definition for "twilight" in, Whether vibration monitoring is activated, Whether illuminance change can cause device wakeup, Whether to reverse which position the sensor consideres "open", Reverse which position the sensor consideres "open", Set whether illuminance change can cause device wakeup, Whether door/window sensor self-checks OK, Whether the internal luminance sensor is operating properly, If vibration is detected, displays validity time in seconds, URL to access when there is a mild gas alarm, URL to access when there is a heavy gas alarm, 12 or 30, Range of the adc (0-12V or 12-30V), Current state of the adc, see description below, Automatic flip back timer, seconds. When Rain Mode is enabled, the device will not raise any alarms when water is detected. Not connected to Shelly Cloud or Shelly Cloud disabled. Fast notifications and at least 60 days of 1-minute records storage. Shelly RGBW2 Color supports up to 7 schedule rules. Find more about the config properties in config section, Find the MQTT.GetConfig response properties in config section, Find the MQTT.GetStatus response properties in status section. Shelly Color can operate in two distinct device modes: In Color mode, each output channel: Red, Green, Blue and White is individually controllable. Shelly4Pro also exposes /settings/relay/{index} for setting the channel parameters. Shows current status of each output channel and accepts commands for controlling the channel via /settings. Sie können wählen, ob Sie Shelly mit der Shelly Cloud-Mobilanwendung und dem Shelly Cloud-Dienst verwenden möchten. Optionally you can connect external contactor and control bigger loads in depends of the contactor specifications. Flashing can be done with esptool. This service allows device monitoring and control over the Internet using the accompanying mobile applications. These pages describe the HTTP API exposed by the Shelly family of devices. Shelly Uni reports: The following topics can be used to read and set output channels 0 and 1: The following topic can be used to read the adc channel: Shelly Uni extends the common /settings endpoint with relay and adc specific data and contains the settings for this device and adds /settings/relay/{index} parameters. Shelly Pro 3EM is a Wi-Fi-operated DIN-mountable 3-Phase Energy Meter with Wi-Fi, Bluetooth, and LAN connectivity. Allterco Robotics EOOD haftet nicht für Konformitätsmängel des Geräts, die dadurch verursacht werden, dass der Benutzer die bereitgestellten Updates nicht rechtzeitig installiert. Zudem ist es möglich, den Internetzugang über entsprechende Router Profile zu sperren, damit sich die Shelly Komponente nicht mehr mit dem Internet verbinden kann. Hinweis: This can either be a periodic wakeup or sensor reading change greater than the configured threshold. Shelly Cloud ist ein Dienst, auf den entweder mit einer Android- oder iOS-Mobilanwendung oder mit jedem Internetbrowser unter zugegriffen werden kann https://home.shelly.cloud/. Please note that cloud must be disabled manually before setting a static IP config without a gateway and enabled manually when switching back to dhcp config (/settings/cloud). an announce packet by every Shelly connected to the broker on. Shelly Sense status command gives information about the device and all sensors status. The MQTT component handles configuration and status of the outbound MQTT connection. The regular succession of these zero-crossing events is Phase A followed by Phase B followed by Phase C. If the sequence of zero-crossing events is, instead, Phase A followed by Phase C followed by Phase B, then a phase_sequence error is reported when the Phase sequence error detection option is enabled. Shelly 3EM is a professional 3-phase energy meter with the following features: Shelly 3EM supports up to 20 schedule rules. Will engage after turning Shelly1/1PM OFF, Automatic flip back timer, seconds. Setting the enabled flag for STA mode to 1 will automatically disable AP mode. The Thing id is derived from the service name, so that's the reason why the Thing is named shellyem3 and not shelly3em. Aber Einfach 689 subscribers Subscribe 1 Share 1 view 1 minute ago #Shelly #Smarthome #Smartmeter. For example, shellypro4pm-f008d1d8b8b8/events/rpc: If you have subscribed to the topic correctly, you will start receiving notifications here. In Relay mode, each of the two channels is controlled individually and supports the ON and OFF commands. Represents device configuration: all devices support a set of common features which are described here. Technically you could use a different combination of software if you prefer. Controls the logical "roller" device and retrieves its current status. Shelly Pro 3EM (The Device) is a DIN rail mountable three-phase energy meter. Only available when in AP mode. If the user wants to keep using Shelly without a password, they can set unprotected to hide the warning. Will engage after turning OFF, Automatic flip back timer, seconds. Shelly2.5 has a single logical Roller, but we index the HTTP resources to allow for future devices with more output channels and Roller-s. Visit the product page for detailed information and User Manual: https://shelly.cloud/products/shelly-vintage-smart-home-automation-bulb/. If the LS bit is 1, the value is number of 4 seconds interval in the whole interval. Shelly devices can report their settings and state to an Internet connected cloud service. If set, the device stays in inactive state for the remaining time. Monitor your home, office, or factory, and avoid additional expenses or drops in voltage that can damage your appliances and devices. Register the Shelly device to connect to up to 2 different Wi-Fi networks. Upon power-on, outputs are initialized using one of these strategies: To control Shelly4Pro in Relay mode, use these resources: Shelly 4Pro uses the following topics for each channel. This helps you control the energy flow, getting the most out of your solar panels and wind turbines. Example CoIoT description (/cit/d) and status (/cit/s): Common attributes apply for the /settings endpoint. Requesting this endpoint will trigger a calibration procedure to be performed. The device will reboot with the factory defaults into AP mode. Setting URLs and. Requesting this endpoint will power off the device. The consent submitted will only be used for data processing originating from this website. Then the response to this request will be published on topic mynewtopic/rpc. Shelly1/1PM supports the ON and OFF commands which control the coil of a 16A 250VAC relay. Jede Änderung der Anschlüsse muss durchgeführt werden, nachdem sichergestellt wurde, dass keine Voltage an den Geräteanschlüssen vorhanden.⚠ VORSICHT! Once this completes successfully, Shelly2 will be able to not only open and close, but target a specific position between the two. In order to apply the MQTT configuration, the device requires a reboot. Shelly1L supports the following actions, which can be set as described at /settings/actions: /status is extended with information about the current state of the output channel as well as data from the power meter. Limited to 300 characters. Since v1.4.3: on MQTT connect, Shellies will publish: Device state is reported periodically, every 30 seconds by default. The returned document is identical to the one returned by /settings in the wifi_sta key. Again, on the /online topic you will receive a message true to notify you for the reconnection. Hier kann man Szenen erstellen, also einfache Wenn-Dann-Abfolgen. Set the period of time in milliseconds before each CoIoT update. A JSON payload will be published by Shelly Bulb RGBW on: The mode of operation of Shelly Bulb RGBW can be set here, along with other standard settings. Shelly devices implement a CoAP-based protocol for monitoring which we call CoIoT. Immer wieder gibt es Probleme beim Verbinden von neuen Shelly Produkten mit der App. Note that the setup process is related to the MQTT system component and the communication over MQTT is described in the MQTT RPC channel page. ⚠CAUTION! the valid certificates, the connection is established. 94x19x69 ±0.5 mm / 3.70x0.75x2.71 ±0.02 in, 0.5 to 2.5 mm² / 20 to 14 AWG (solid, stranded, and bootlace lugs). Shelly Dimmer 1/2 supports the following actions, which can be set as described at /settings/actions: Specify a startup warmup brightness for a short period of time. Please note, these errors can depend on your browser setup. All sensors are required to be emitted in channel 0. To control Shelly Uni, use these resources: Shelly Uni allows control and monitoring over MQTT. Shelly 1L supports up to 18 schedule rules. Example CoIoT description (/cit/d) and status (/cit/s) are provided separetely for each device: Shelly1 is the smallest intelligent Wi-Fi power switch on the market today. Montieren Sie Schutzschalter gemäß Ihren örtlichen Vorschriften und verbinden Sie die Kabel der Phase A, Phase B und Phase C durch sie mit den Eingängen von Gerät A, B bzw. Shelly i3 supports the following actions, which can be set as described at /settings/actions: The returned document here is identical to the data returned in /settings for the particular input channel in the inputs array. Enable/Disable autodetecting the timezone. Shelly devices include basic MQTT support since version 1.3.0. Such events are for example shortpush/longpush of buttons – devices will send a property of type “EV” to denote the exact event type (“S” = shortpush, “L” = longpush), and a property of type “EVC” that will increment its value when a new event occurs (e.g. Dies kann mit einem Phasenprüfer oder Multimeter erfolgen. Then, open the window where you subscribed to the topic /events/rpc. Shelly Motion 2 supports the following actions, which can be set as described at /settings/actions: To restore Shelly Motion 2 to its factory settings, turn the device on if needed, then press and hold the user button for > 10 seconds. AVM Fritzbox oder Linksys, Telekom Speedport, NetGear Nighthawk, D-Link, TP-Link, etc.) All responses are piggyback sent with the acknowledgement to further simplify CoAP implementation. When configured for MQTT Shelly H&T sends values from its internal sensors on the following topics: Shelly HT accepts the following extra parameters on it's /settings endpoint: Shelly H&T supports the following actions, which can be set as described at /settings/actions: Sensor values are repoted on the /status endpoint, along with info on the reason the device is awake.